Unbenanntes Dokument
Hochspannungssteckverbinder Hochspannungssteckverbinder
Hochspannungssteckverbinder
HV-Technik
HV-Connectors
GES Newsletter
HV-Feedthrough
High Voltage Technology
 
 
High Voltage Connectors
 
High Voltage Assemblies
High Voltage Cable Assemblies
High Voltage Connectors

single-pin HV-Connectors

PROPERTIES VALUE STANDARD
General properties Value Standard
Number of contacts 1
Termination technique screw / solder
Mounting (device side) central flange
Flammability HB / V-0 (POM / PTFE) UL 94
Electrical properties Value Standard
Testing voltage DC 90 kV
Operating voltage DC 60 kV IEC 60664-1
Operating voltage AC (eff., 60Hz) 42 kV IEC 60664-1
Material group insulation 1 IEC 60664-1
Pollution degree 2 IEC 60664-1
Current carrying capacity 50 A IEC 60512-3, Test 4a
Contact resistance 200 µΩ IEC 60512-2, Test 2a
Insulation resistance 1016 Ω (contact to housing) IEC 60512-2, Test 3a
Climatical properties Value Standard
Lower temperature -20 °C / -50 °C * (POM / PTFE)
Upper temperature +100 °C / +200 °C * (POM / PTFE)
Mechanical properties Value Standard
Mating- / unmating force (contacts) 15 N / 10 N IEC 60512-7, Test 13b
Mating cycles ≥ 100T
Materials Value Standard
Insulation sleeves POM / PTFE * (white)
Contacts Cu-alloy
Contact plating Ag
Housing AI, nickel plated
     
CONTACTS & CABLES VALUE STANDARD
HV-Contacts Value Standard
Contact diameter 5 mm
Max. outer diameter - male 4 mm
Max. outer diameter - female 2,8 mm (solder) / 4 mm (cable lug)
Diameter - wire gauge max. 6 mm²
HV-Cables Value Standard
Suitable cable type screened (Coax) or unscreened
Max. outer diamete - screened 7 - 14 mm *
Max. outer diameter - unscreened 10 mm
Max. inner insulation diameter 10 mm
Technical subject to change without prior notice | state of revision 0709 | * dependent on type and assembly variant
TESTING ADVICE: Ratings listed in this table apply to clean connector pairs in standard athmospheric conditions. No warranty or merchantability or fitness for a particular purpose is made and all customers must test each component to determine that it meets their operating and reliability requirements. When connectors are used in an adverse environment, other than stated - such as high temperature, humidity, pollution content, extreme mechanical exposure etc. - the connector should be derated.
SECURITY ADVICE: Please be aware that design, installation and inspection of machinery and devices carrying high voltage urgently require accordingly trained and qualified personnel. Improper handling of high voltage can mean severe injuries or even death and may cause serious collateral damage!
HV-Feedthroughs
High Voltage Technology
High Voltage Connectors
High Voltage Assemblies
HV-Connectors
HV-DurchführungGES Electronic & Service GmbH
HochspannungstechnikZeppelinstr. 4, Haus 3
Hochspannungssteckverbinder85399 Hallbergmoos / Germany
HochspannungsdurchführungTel.: +49 (0)811 / 541 548 - 0
HV-TechnikFax: +49 (0)811 / 541 548 - 99
HV-Steckverbinder
 
HV-Feedthroughs
PRODUCTS | APPLICATIONS | COMPANY | CONTACT / IMPRINT | START Deutsch
Copyright 2010 GES Electronic & Service GmbH | V 4.5 | realized in cooperation with bureau Landegaard