single-pin HV-Connectors
| PROPERTIES |
VALUE |
STANDARD |
| General properties |
|
|
| Number of contacts |
1 |
|
| Termination technique |
screw / solder |
|
| Mounting (device side) |
central flange |
|
| Flammability |
V-0 |
UL 94 |
| Electrical properties |
|
|
| Testing voltage DC |
15 kV |
|
| Operating voltage DC |
10 kV |
IEC 60664-1 |
| Operating voltage AC (eff., 60Hz) |
7 kV |
IEC 60664-1 |
| Material group insulation |
1 |
IEC 60664-1 |
| Pollution degree |
2 |
IEC 60664-1 |
| Current carrying capacity |
25 A |
IEC 60512-3, Test 4a |
| Contact resistance |
300 µΩ |
IEC 60512-2, Test 2a |
| Insulation resistance |
1016 Ω (contact to housing) |
IEC 60512-2, Test 3a |
| Climatical properties |
|
|
| Lower temperature |
-50 °C |
|
| Upper temperature |
+200 °C |
|
| Mechanical properties |
|
|
| Mating- / unmating force (contacts) |
5,5 N / 4 N |
IEC 60512-7, Test 13b |
| Mating cycles |
≥ 100T |
|
| Materials |
|
|
| Insulation sleeves |
PTFE |
|
| Contacts |
Cu-alloy |
|
| Contact plating |
Ag / Au * |
|
| Housing |
AI, nickel plated |
|
| |
|
|
| CONTACTS & CABLES |
VALUE |
STANDARD |
| HV-Contacts |
|
|
| Contact diameter |
2,5 mm |
|
| Max. outer diameter - male |
2,3 mm |
|
| Max. outer diameter - female |
1,6 mm (solder) / 2,5 mm (cable lug) |
|
| Diameter - wire gauge |
max. 3 mm² |
|
| HV-Cables |
|
|
| Suitable cable type |
screened (Coax) or unscreened |
|
| Max. outer diamete - screened |
7 - 14 mm * |
|
| Max. outer diameter - unscreened |
10 mm |
|
| Max. inner insulation diameter |
10 mm |
|
Technical subject to change without prior notice | state of revision 0709 | * dependent on type and assembly variant
TESTING ADVICE: Ratings listed in this table apply to clean connector pairs in standard athmospheric conditions. No warranty or merchantability or fitness for a particular purpose is made and all customers must test each component to determine that it meets their operating and reliability requirements. When connectors are used in an adverse environment, other than stated - such as high temperature, humidity, pollution content, extreme mechanical exposure etc. - the connector should be derated.
SECURITY ADVICE:
Please be aware that design, installation and inspection of machinery and devices carrying high voltage urgently require accordingly trained and qualified personnel. Improper handling of high voltage can mean severe injuries or even death and may cause serious collateral damage!
|  |
 |
|
|
 |
 |
Services
- back to overview
- CONFIGURATOR / INQUIRY
- SOURCING / INQUIRY
- E-Mail Support
-
Save / print as PDF
Links & Downloads
- SB 110 - Dimensions