Amphenol C146M
Wieland revos FLEX
Weidmüller Rockstar

hybrid HV-Connectors / System Components

PROPERTIES PNEUMATICAL VALUE ELECTRICAL VALUE STANDARD
General properties
Number of valves / contacts 1 2
Termination technique self-retentive crimp
Contact diameter
Wire gauge 2,5 / 4 mm 1.5 - 10 mm² (AWG 16 - 8)
Flammability
V-0
UL 94
Pneumatical properties
Testing pressure 10 bar / 145 psi
Operating pressure 8 bar / 116 psi
Operating path 4 mm
Locking locking on one side
Tube type preferably PTFE
Max. outer tube diameter 8 mm
Electrical properties
Rated voltage 630 V
Pollution degree 3 IEC 60664-1
Installation (overvoltage) category 3 IEC 60664-1
Material group (insulation) 2 (PA) IEC 60664-1
Rated impulse withstand voltage 8 kV IEC 60664-1
Voltage proof 4.26 kV IEC 60512-2, Test 4a
Current carrying capacity 40 A IEC 60512-3, Test 5b
Contact resistance ≤ 1 mΩ IEC 60512-2, Test 2a
Insulation resistance ≥ 1012 Ω IEC 60512-2, Test 3a
Clearance / Creepage > 12 mm IEC 60664-1
Climatical properties
Upper temperature
+ 100 °C
IEC 60512-6, Test 11 i
Lower temperature
- 20 °C
IEC 60512-6, Test 11 i
Mechanical properties
Mating cycles (contacts)
≥ 500
IEC60512-5, Test 9a
Materials
Valve / Contacts Brass MS 58 Cu-alloy
Contact plating Ag
Sealings NBR / EPDM / FKM
Module body
PA 6.6 GF
Colour
black
Technical subject to change without prior notice | state of revision 0709 | * dependent on type and assembly variant
TESTING ADVICE: Ratings listed in this table apply to clean connector pairs in standard athmospheric conditions. No warranty or merchantability or fitness for a particular purpose is made and all customers must test each component to determine that it meets their operating and reliability requirements. When connectors are used in an adverse environment, other than stated - such as high temperature, humidity, pollution content, extreme mechanical exposure etc. - the connector should be derated.
LAPP EPIC MC
Walther Procon MO
Amphenol C146M
Wieland revos FLEX
LAPP EPIC MC
HV-DurchführungGES Electronic & Service GmbH
HochspannungstechnikZeppelinstr. 4, Haus 3
Hochspannungssteckverbinder85399 Hallbergmoos / Germany
HochspannungsdurchführungTel.: +49 (0)811 / 541 548 - 0
HV-TechnikFax: +49 (0)811 / 541 548 - 99
HV-Steckverbinder
 
heavy duty industrial connectors
PRODUCTS | APPLICATIONS | COMPANY | CONTACT / IMPRINT | START Deutsch
Copyright 2010 GES Electronic & Service GmbH | V 4.5 | realized in cooperation with bureau Landegaard